Yueniao High Head Micro Hydroelectric
Generator
Power
outputs: 200W - 30000W,
1)
Three phase, 380V/50HZ or 60HZ
For models XJ30-12SCT4-Z, XJ30-15SCT4/6-Z, XJ3020SCT4/6-Z,
XJ38-30SCT4/6-Z
2) Single phase, 110V or 230V/50HZ or 60HZ
For all the rest of the models

This
PowerPal High Head Series offers a complete water to wire
system with integral turgo turbine, generator and valve
flow control. All or part of the stream flow is diverted
through steel penstock pipe and down to the turbine. The
flow then escapes and is carried away along a drainage trench.
Output voltage and frequency are controlled by our electronic
load controller (with ballast). The bearings are sealed
and need replacing every few years - no other maintenance
is necessary. If submerged in water simply dry Yueniao in
the sun and use again. This series also comes complete with
its own ELC and the voltage range is the same as for the
Low Head Models. This Turgo Series is compact and easy to
install by anyone with a practical nature.
These
machines are built to be relied upon in remote locations
and withstand harsh conditions. Innovative designs, high
efficiency and sophisticated but simple electronic controls
ensure years of reliable electricity.
| Model |
Head
Range
(meters)
|
Flow
Range
(liter/second)
|
Power
(W)
|
Nozzle
/valve numbers
|
Penstock
Diameter
(mm)
|
Packing
Size
(cm)
|
| XJ14-0.2DCT4-Z |
10
~ 14 |
3
~ 4 |
200 |
single |
50 |
30x26x27 |
| XJ14-0.3DCT4-Z |
12
~ 14 |
3
~ 5 |
300 |
single |
50 |
26x30x34 |
| XJ18-0.5DCT4-Z |
12
~ 18 |
5
~ 7 |
500 |
single |
50-75 |
26x30x36 |
| XJ18-0.75DCT4-Z |
14
~ 18 |
5
~ 8 |
750 |
single |
75 |
35x35x53 |
| XJ22-1.1DCT4-Z |
16
~ 22 |
8
~ 10 |
1100 |
single |
100 |
77x51x52 |
| XJ22-1.1DCT4-Z2 |
15 |
10
~ 15 |
1100 |
double |
125-150 |
77x51x52 |
| XJ25-1.5DCT4-Z |
18
~ 25 |
8
~ 11 |
1500 |
single |
125 |
80x56x58 |
| XJ25-1.5DCT4-Z2 |
15 |
12
~ 18 |
1500 |
double |
125-150 |
80x56x58 |
| XJ25-3.0DCT4-Z |
25
~ 35 |
15
~ 19 |
3000 |
single |
125-150 |
62x52x72 |
| XJ25-3.0DCT4-Z2 |
18
~ 20 |
18
~ 30 |
3000 |
double |
150 |
90x64x65 |
| XJ28-6.0DCT4-Z |
28
~ 35 |
30
~ 38 |
6000 |
single |
150-200 |
75x65x82 |
| XJ28-6.0DCT6-Z |
18
~ 20 |
38
~ 50 |
6000 |
double |
200 |
106x76x73 |
| XJ30-10DCT4-Z |
30
~ 38 |
40
~ 50 |
10000 |
single |
200-250 |
110x78x86 |
| XJ30-10DCT6-Z |
25
~ 30 |
50
~ 60 |
10000 |
double |
200-250 |
110x78x86 |
| XJ30-12SCT4-Z |
28
~ 35 |
50
~ 60 |
12000 |
double |
200-250 |
|
| XJ30-15SCT4/6-Z |
30
~ 40 |
60
~ 70 |
15000 |
double |
200 |
120x90xx105
80x60x50
|
| XJ30-20SCT4/6-Z |
30
~ 45 |
60
~ 80 |
20000 |
double |
250-300 |
20x90xx105
80x60x50
|
| XJ38-30SCT4/6-Z |
38
~ 45 |
90
~ 120 |
30000 |
double |
250-300 |
|
It
is important to keep in mind that output can only be accurately
determined if head and flow measurements are made correctly,
so care should be taken during this process. Two other important
factors in a site assessment are system voltage, and transmission
distance. The voltage and distance the power must travel
can affect the efficiency and cost of your transmission