INV
Series inverter supply is the static sine wave one mainly
for posts and telecommunications, railway and electric system
in which DC power is supplied for AC equipment. The isolating
transformer output makes inverter own superstrong overload
capacity. This series is applicable for many system such as
power equipment, communication system, server and computer
network and provides higher-grade elecreic power supply for
them. While AC is abnormal or DC is used up, it will automatically
switch into DC/AC power supply so as to ensure the safety
of the system on higher degree.

| Model |
|
|
|
|
|
|
|
|
|
|
Rated
power |
400W |
800W |
1600W |
2400W |
4000W |
8000W |
12000W |
16000W |
24000W |
32000W |
DC
Input voltage |
24VDC(20~30VDC) |
|
48VDC(40~60VDC) |
|
| |
110VDC(90~130VDC) |
|
| |
220VDC(170~260VDC) |
Working |
While
AC bypass mainly supplies electricity, DC inversion
is for standby;
While
DC inversion mainly supplies electricity, DC bypass
is for standby; automatic switching. |
Bypass
input voltage(AC) |
220V±20% |
Bypass
input frequency(Hz) |
50±2.5Hz |
| Output |
Voltage(AC) |
220±2% |
| Frequency |
50Hz±0.5% |
Wave
form |
Sine
wave |
| Wave
distortion |
THD<3%
(Linear load) |
Rated
power |
0.8
lag |
| Current
peak coefficient |
3:1,
suitable for rectifying load |
| Transient
range of dynamic voltage |
0-100%
load change, < ±6% |
| Overload
capacity |
While
exceeding 120% rated load, the machine can alarm and
close. |
Efficiency |
>81% |
| Noise(1
meter distance) |
<55dB |
Protection |
Protection
against overcurrent, protection against overloas, protection
against input voltage |
| LED
indicator light |
The
states of mains supply, inversion, overload and battery,
etc |
LCD
liquid crystal display |
Input/output
voltage, Input/output frequency, battery voltage and
load percentage |
Warn |
Low
voltage of battery |
Pulsed
sound per second |
Overload |
Successive |
| Machine
fault |
Successive |
| Computer
control interface |
RS232
interface |
Real
time monitoring and controlling the working state of machine,
warning of mains supply failure, warning of low woltage
of battery, saving documwnts as well as closing the machine. |
1.
Telemeter the input/output voltage and frequency of
machine, load, battery capacity which will be shown
appropriately on PC machine
2.
Real time telemetering the working state of machine
3.
Preset the machine function of starting & closing
machine through PC
4.
Before battery is used up, it can automatically save
documents, close PC and then close itself. |
| Using
environment |
Temperature |
0-40℃ |
| Relative
humidity |
30%-90%
no condensation |
| Height
above sea level |
<1000m
(the power will drop 1% per increase of 100m, max.:4000m) |
Weight(kg) |
16 |
19.1 |
30.3 |
33.5 |
83 |
171 |
220 |
257 |
287 |
342 |
| Overall
dimensions(mm) |
Length |
515 |
560 |
635 |
550 |
790 |
Width |
180 |
210 |
270 |
450 |
580 |
| Height |
315 |
370 |
690 |
1000 |
1180 |
If
there are any changes in specification, we wont inform you
separately. In addition, order for special specification is
accepted.
|